Unihedron Sky Quality Meter with Lens - Narrow Field of View / RS232 Connection

Stock count is accurate & shown in real time.
- This item is out of stock.
- Sign up for back-in-stock alerts to be notified when this item becomes available.
- This item is out of stock.
- We have no ETA from the manufacturer at this time.
- Sign up for back-in-stock alerts to be notified when this item becomes available.
Lower 48 States:
Orders over $50 ship free within the Lower 48 using a carrier and service we select based on your items and delivery location. Faster shipping options may be available at checkout.
U.S. Outside the Lower 48 (AK, HI, PR):
Free shipping on orders over $50 applies to many—but not all—items. Add items to your cart and enter your ZIP code to see available shipping options and any costs.
International Orders:
Free shipping does not apply to international orders. You’ll see available shipping options and costs during checkout. Some items can’t be shipped internationally due to size or manufacturer restrictions. Duties, taxes, brokerage fees, and tariffs are not included and are the customer’s responsibility.
An affordable meter for continual, connected measuring of sky brightness for astronomers! The "Sky Quality Meter - LR" measures the brightness of the night sky in magnitudes per square arcsecond. Designed by Dr. Doug Welch and Anthony Tekatch, the Unihedron Sky Quality Meter offers unprecedented sensitivity in a handheld meter.
Uses:
- Find out how good the night or site REALLY is.
- Compare the sky brightness at different sites quantitatively.
- Document the evolution of light pollution in your area.
- Set planetarium dome illumination to mimic the skies people are likely to experience elsewhere in the city.
- Monitor sky brightness through the night, night-to-night, and year-to-year.
- Determine which nights show the greatest promise for finding the 'faintest fuzzies'!
- Calibrate the effect of sky brightness on qualitative measures such as the Bortle Scale.
- Investigate how sky brightness correlates with the solar cycle and month-to-month sunspot activity.
- Help provide local ground truth for future sky brightness prediction with the Clear Sky Clock.
- CCD users can make a correlation between the SQM reading and when the background reaches some ADC level.
Deployment
- Legacy computer interface installations.
- MODEM interface installations.
- Simple electronic interface projects.
Features:
- Sky brightness reported in visual magnitudes per square arcsecond.
- Infrared blocking filter restricts measurement to visual bandpass.
- Sensor temperature, model number, and serial number are provided.
- Precision readings at even the darkest sites.
- Field-upgradeable firmware.
- Open protocol document.
Specifications:
- RS232 connectivity.
- Included applications for reading data in Perl.
- The Half Width Half Maximum (HWHM) of the angular sensitivity is ~10°. The Full Width Half Maximum (FWHM) is then ~20°. The sensitivity to a point source ~19° off-axis is a factor of 10 lower than on-axis. A point source ~20° and ~40° off-axis would register 3.0 and 5.0 magnitudes fainter, respectively.
- Size 3.6 x 2.6 x 1.1 in.
- Maximum light sampling time: 80 seconds.
- Minimum light sampling time: 1 seconds.
- Specifications are subject to change without notice.
What You Get:
- SQM-LR unit
- International AC adapter
- SQM-LR users manual
- USB flash drive containing the users manual, operation software (UDM), and example software. This can also be found online here.
- 6ft RS232 straight through cable
- Calibration sheet indicates unit serial number and calibration values
Other Information
- Country of Manufacture: Canada
An affordable meter for continual, connected measuring of sky brightness for astronomers! The "Sky Quality Meter - LR" measures the brightness of the night sky in magnitudes per square arcsecond. Designed by Dr. Doug Welch and Anthony Tekatch, the Unihedron Sky Quality Meter offers unprecedented sensitivity in a handheld meter.
Uses:
- Find out how good the night or site REALLY is.
- Compare the sky brightness at different sites quantitatively.
- Document the evolution of light pollution in your area.
- Set planetarium dome illumination to mimic the skies people are likely to experience elsewhere in the city.
- Monitor sky brightness through the night, night-to-night, and year-to-year.
- Determine which nights show the greatest promise for finding the 'faintest fuzzies'!
- Calibrate the effect of sky brightness on qualitative measures such as the Bortle Scale.
- Investigate how sky brightness correlates with the solar cycle and month-to-month sunspot activity.
- Help provide local ground truth for future sky brightness prediction with the Clear Sky Clock.
- CCD users can make a correlation between the SQM reading and when the background reaches some ADC level.
Deployment
- Legacy computer interface installations.
- MODEM interface installations.
- Simple electronic interface projects.
Features:
- Sky brightness reported in visual magnitudes per square arcsecond.
- Infrared blocking filter restricts measurement to visual bandpass.
- Sensor temperature, model number, and serial number are provided.
- Precision readings at even the darkest sites.
- Field-upgradeable firmware.
- Open protocol document.
Specifications:
- RS232 connectivity.
- Included applications for reading data in Perl.
- The Half Width Half Maximum (HWHM) of the angular sensitivity is ~10°. The Full Width Half Maximum (FWHM) is then ~20°. The sensitivity to a point source ~19° off-axis is a factor of 10 lower than on-axis. A point source ~20° and ~40° off-axis would register 3.0 and 5.0 magnitudes fainter, respectively.
- Size 3.6 x 2.6 x 1.1 in.
- Maximum light sampling time: 80 seconds.
- Minimum light sampling time: 1 seconds.
- Specifications are subject to change without notice.
What You Get:
- SQM-LR unit
- International AC adapter
- SQM-LR users manual
- USB flash drive containing the users manual, operation software (UDM), and example software. This can also be found online here.
- 6ft RS232 straight through cable
- Calibration sheet indicates unit serial number and calibration values
An affordable meter for continual, connected measuring of sky brightness for astronomers! The "Sky Quality Meter - LR" measures the brightness of the night sky in magnitudes per square arcsecond. Designed by Dr. Doug Welch and Anthony Tekatch, the Unihedron Sky Quality Meter offers unprecedented sensitivity in a handheld meter.
Uses:
- Find out how good the night or site REALLY is.
- Compare the sky brightness at different sites quantitatively.
- Document the evolution of light pollution in your area.
- Set planetarium dome illumination to mimic the skies people are likely to experience elsewhere in the city.
- Monitor sky brightness through the night, night-to-night, and year-to-year.
- Determine which nights show the greatest promise for finding the 'faintest fuzzies'!
- Calibrate the effect of sky brightness on qualitative measures such as the Bortle Scale.
- Investigate how sky brightness correlates with the solar cycle and month-to-month sunspot activity.
- Help provide local ground truth for future sky brightness prediction with the Clear Sky Clock.
- CCD users can make a correlation between the SQM reading and when the background reaches some ADC level.
Deployment
- Legacy computer interface installations.
- MODEM interface installations.
- Simple electronic interface projects.
Features:
- Sky brightness reported in visual magnitudes per square arcsecond.
- Infrared blocking filter restricts measurement to visual bandpass.
- Sensor temperature, model number, and serial number are provided.
- Precision readings at even the darkest sites.
- Field-upgradeable firmware.
- Open protocol document.
Specifications:
- RS232 connectivity.
- Included applications for reading data in Perl.
- The Half Width Half Maximum (HWHM) of the angular sensitivity is ~10°. The Full Width Half Maximum (FWHM) is then ~20°. The sensitivity to a point source ~19° off-axis is a factor of 10 lower than on-axis. A point source ~20° and ~40° off-axis would register 3.0 and 5.0 magnitudes fainter, respectively.
- Size 3.6 x 2.6 x 1.1 in.
- Maximum light sampling time: 80 seconds.
- Minimum light sampling time: 1 seconds.
- Specifications are subject to change without notice.
What You Get:
- SQM-LR unit
- International AC adapter
- SQM-LR users manual
- USB flash drive containing the users manual, operation software (UDM), and example software. This can also be found online here.
- 6ft RS232 straight through cable
- Calibration sheet indicates unit serial number and calibration values
Other Information
- Country of Manufacture: Canada
| Free Shipping Graphic | Free US Shipping |
|---|---|
| Hide Found a better Shipped Price on Frontend? | No |

Unihedron Sky Quality Meter with Lens - Narrow Field of View / RS232 Connection


















